You will need to carry out a manual RCD test. Firstly test the multibox using test code 168 for a IT/surge type multibox. If it passes this test select; Manual Tests , RCD, 15mA test option. Contact us for free if you need further advice.
Archives: FAQs
Do I need to connect the earth bond test lead during a 500 Volt Insulation Resistance test.
Yes you do. If the test lead is not connected the tester will not give a correct reading, you could potentially pass an appliance that should fail this test.
During an earth continuity test there are sparks where my earth bond test lead is connected. What does this mean?
Check that there is a good connection between your test lead and the metal you are measuring to. If it is dirty or corroded you can see sparking. If you have doubts about proceeding with tests seek further advise.
Can all office equipment be tagged with a five year expiry date?
Generally no, this depends on the set up of the equipment and the workplace environment. Refer to AS/NZS 3760 for definitions of hostile and non-hostile environments. Quite often offices should only be tagged for 12 months.
Are there appliances or equipment I am legally not allowed to DIY test (must be tested by a professional)?
Yes. There are special requirements for areas like patient treatment areas, hospitals etc, along with boat marinas and areas classified as hazardous also require specific training and EWRB electrical registration along with a current Practicing Licence.
What appliances or electrical equipment can I DIY test?
Equipment found in a normal workplace, including 3-Phase equipment can be tested by a ‘Competent’ person with sufficient skill and the right test equipment. If, however, equipment needs to be dismantled for the testing then an EWRB registered electrical person with a current Practicing Licence is required to do the testing.