FAQ’s
DIY Test And Tag
Yes. There are special requirements for areas like patient treatment areas, hospitals etc, along with boat marinas and areas classified as hazardous also require specific training and EWRB electrical registration along with a current Practicing Licence.
Check that there is a good connection between your test lead and the metal you are measuring to. If it is dirty or corroded you can see sparking. If you have doubts about proceeding with tests seek further advise.
Yes you do. If the test lead is not connected the tester will not give a correct reading, you could potentially pass an appliance that should fail this test.
You will need to carry out a manual RCD test. Firstly test the multibox using test code 168 for a IT/surge type multibox. If it passes this test select; Manual Tests , RCD, 15mA test option. Contact us for free if you need further advice.